November 2019

Voipblock for DGA4130 and DA4132: calls blacklist for Smart Modem Plus and TIM HUB

Thanks to the joint effort of an entire community it has been possible to unlock many modems/routers produced by Technicolor and based on OpenWrt Chaos Calmer 15.05.1, including the Smart Modem Plus DGA4130 (AGTEF) and the TIM HUB DGA4132 (AGTHP). After unlocking it is also possible to install a GUI that allows access to all the features of the device. More info can be found here , here and here . The hard-working community has also proposed several implementations of a system to create a calls blacklist, some implementations use the iptables firewall, other implementations use asterisk. Below is a new solution called Voipblock, which also uses the iptables firewall but is slightly different from the others: fully integrated with the iptables firewall completely manageable from the...

Remove Green Power function from UPS: allow UPS work with low load

Does your UPS turn off after exactly 5 minutes? Quiet, it's not broken, it's the fault of the Green Power function. In the past years, in fact, several brands manifactured their UPS with a function called Green Power, and due to Green Power function the UPS shutdown in 5 minutes when it is on battery and the total load on the UPS is equal or less than 10% of the UPS capacity, therefore if there...